1. How to check the error code from Pimax Play?

Open Pimax Play interface, click the blue icon after "Disconnect" by mouse.


2. Error code 105XX

a. Error code 10500


Cause: USB not recognized when connecting the headset to the computer


Solution:

· Please make sure that the USB head of the DP cable is connected to a USB port on the PC with a speed higher than USB3.0

· For laptops, please make sure that the computer interface supports direct connection to the independent graphics card and the adapter used supports DP1.4

· Please make sure that the DP cable on the head display is plugged in tightly and not dislocated (as shown below)

· Please make sure that the power adapter is plugged into a power source with an appropriate voltage range and the switch is turned on.

· Please make sure that the power adapter interface is correctly connected to the DP cable


b. Error code 10517
Cause: USB failed to read device information


Solution: Restart the headset and restart the computer


c. Error code 10518
Cause: Abnormal positioning information of the headset  


Solution: Delete the directory (%programdata%\pimax\slam) and restart the service


3. Error code 106XX

a. Error code 10600

Cause: Graphics card DP is not recognized


Solution:

· Please make sure that the DP port of the data cable is connected to the DP port of the independent graphics card

· Please make sure that the DP cable on the head display is plugged in tightly and not dislocated (as shown below)

· Graphics card driver problem, please update the driver from the graphics card official website


b. Error code 10632/10636

Cause: Graphics card or DP cable problem


Solution:

· Re-plug the display cable

· Install the graphics driver

· Restart the operating system


3. Error code 109XX

a. Error code 10900

Cause: The helmet DP port is connected to the integrated graphics card/the graphics card does not support direct connection mode/the graphics card driver is too old


Solution:

· Plug the helmet display device into the independent graphics card

· Replace the graphics card driver

· Check the graphics card model and confirm whether it is lower than the minimum graphics card requirement


b. Error code 10932

Cause: Graphics card or DP cable problem


Solution:

· Re-plug the DP cable

· Install the graphics driver

· Restart the operating system


c. Error code 10933

Cause: The device has been used


Solution:

· Replug the DP port

· Switch the DP port or restart the computer


d. Error code 10934

Cause: Integrated/core graphics card detected


Solution: Disable the integrated/core graphics card from BIOS setting, not from the device manager.


5. Error code 10935/10936
Cause: Unable to initialize the HMD screen


Solution:

· Unplug DP or restart the computer

· Replace the data cable or DP port


6. Error code 10938

Cause: Exceeding the graphics card bandwidth


Solution:

· Remove extra display devices

· Reduce display resolution and refresh rate


4. Error code 20XXX

a. Error code 20000
Cause: USB not recognized when connecting the headset to the computer


Solution:

· Re-plug the USB

· If it is a problem with the operating system USB driver, you can try to uninstall the driver and download the driver from the motherboard official website.


b. Error code 20100

Cause: Pimax Play file installation error


Solution: Reinstall the Pimax Play 


c. Error code 20300/20400

Cause: Headset device acquisition failed


Solution: Restart the client and reinstall the client


d. Error code 20800

Cause: VR service connection failed


Solution: Restart the service


e. Error code 29001

Cause of failure: Pimax Play internal data communication is abnormal


Solution: Restart the service


5. Error code 30XXX

a. Error code 30000

Cause: Pimax Play service is abnormal


Solution: Restart the client and reinstall the Pimax Play  



b. Error code 30101

Cause: Algorithm problem


Solution: Delete the directory (%programdata%\pimax\slam) and restart the service


c. Error code 30202/30204

Cause: Pimax Play and headset communication abnormality


Solution: Please wait. If the waiting time is too long, please restart the headset and restart the service.


d. Error code 30205

Cause: Communication between Pimax Play and the headset timed out


Solution: Restart the computer or reinstall the Pimax