A: First complete the eye tracking calibration, then use the client's export log function to export the logs and provide them to technical support for analysis. At the same time, you can use your phone's camera function to photograph the area on one side of the headset's lenses while the headset is connected, to confirm whether each of the 10 eye-tracking IR lights for the left and right eyes is lit.

I. If the eye-tracking IR lights are not lit, please troubleshoot in order:

  1. If other Tobii eye-tracking devices are connected to the PC at the same time, please unplug them.

  2. If the headset is connected using an extension cable, please remove the extension cable and connect the headset directly to a USB 3.0 port on the motherboard; if the motherboard has a USB 3.2 port, try plugging it into that port.

  3. Close the client and disconnect the headset. 
    Open Device Manager → click "View" → click "Show hidden devices" → click "Universal Serial Bus devices" 
    and delete all eyechip devices; then click "Cameras," remove the related devices under it, then restart the client 
    and connect the headset for testing.

  1. Try a complete cold boot: disconnect all headset cables, also disconnect the power supply to the powered USB hub, wait about 20 seconds, then reconnect the headset and check whether it recovers.

  2. Disable the power-saving mode for the USB port corresponding to the headset, and set the system power mode to High Performance.

If the eye-tracking IR lights still do not light up after the above troubleshooting steps, please contact technical support, who will further confirm in conjunction with the logs.

II. If the eye-tracking IR lights are lit normally, but eye tracking calibration fails, please try:

  1. During calibration, move appropriately closer to or farther from the headset and observe whether calibration succeeds.

  2. Set the IPD to the minimum or maximum and observe whether calibration succeeds.

  3. If there are stains on the lenses, please wipe them clean with a glasses cloth before attempting eye tracking calibration again.